45 research outputs found

    A 1D continuum model for beams with pantographic microstructure: asymptotic micro-macro identification and numerical results

    Get PDF
    In the standard asymptotic micro-macro identification theory, starting from a De Saint-Venant cylinder, it is possible to prove that, in the asymptotic limit, only flexible, inextensible, beams can be obtained at the macro-level. In the present paper we address the following problem: is it possible to find a microstructure producing in the limit, after an asymptotic micro-macro identification procedure, a continuum macro-model of a beam which can be both extensible and flexible? We prove that under certain hypotheses, exploiting the peculiar features of a pantographic microstructure, this is possible. Among the most remarkable features of the resulting model we find that the deformation energy is not of second gradient type only because it depends, like in the Euler beam model, upon the Lagrangian curvature, i.e. the projection of the second gradient of the placement function upon the normal vector to the deformed line, but also because it depends upon the projection of the second gradient of the placement on the tangent vector to the deformed line, which is the elongation gradient. Thus, a richer set of boundary conditions can be prescribed for the pantographic beam model. Phase transition and elastic softening are exhibited as well. Using the resulting planar 1D continuum limit homogenized macro-model, by means of FEM analyses, we show some equilibrium shapes exhibiting highly non-standard features. Finally, we conceive that pantographic beams may be used as basic elements in double scale metamaterials to be designed in future

    An Overview on Functional Integration of Hybrid Renewable Energy Systems in Multi-Energy Buildings

    Get PDF
    Buildings are responsible for over 30% of global final energy consumption and nearly 40% of total CO2 emissions. Thus, rapid penetration of renewable energy technologies (RETs) in this sector is required. Integration of renewable energy sources (RESs) into residential buildings should not only guarantee an overall neutral energy balance over long term horizon (nZEB concept), but also provide a higher flexibility, a real-time monitoring and a real time interaction with end-users (smart-building concept). Thus, increasing interest is being given to the concepts of Hybrid Renewable Energy Systems (HRES) and Multi-Energy Buildings, in which several renewable and nonrenewable energy systems, the energy networks and the energy demand optimally interact with each other at various levels, exploring all possible interactions between systems and vectors (electricity, heat, cooling, fuels, transport) without them being treated separately. In this context, the present paper gives an overview of functional integration of HRES in Multi-Energy Buildings evidencing the numerous problems and potentialities related to the application of HRESs in the residential building sector. Buildingintegrated HRESs with at least two RESs (i.e., wind–solar, solar–geothermal and solar–biomass) are considered. The most applied HRES solutions in the residential sector are presented, and integration of HRES with thermal and electrical loads in residential buildings connected to external multiple energy grids is investigated. Attention is focused on the potentialities that functional integration can offer in terms of flexibility services to the energy grids. New holistic approaches to the management problems and more complex architectures for the optimal control are described

    Thermal characterization of recycled materials for building insulation

    Get PDF
    The building sector is known to have a significant environmental impact, considering that it is the largest contributor to global greenhouse gas emissions of around 36% and is also responsible for about 40% of global energy consumption. Of this, about 50% takes place during the building operational phase, while around 10–20% is consumed in materials manufacturing, transport and building construction, maintenance, and demolition. Increasing the necessity of reducing the environmental impact of buildings has led to enhancing not only the thermal performances of building materials but also the environmental sustainability of their production chains and waste prevention. As a consequence, novel thermo-insulating building materials or products have been developed by using both locally produced natural and waste/recycled materials that are able to provide good thermal performances while also having a lower environmental impact. In this context, the aim of this work is to provide a detailed analysis for the thermal characterization of recycled materials for building insulation. To this end, the thermal behavior of different materials representing industrial residual or wastes collected or recycled using Sardinian zero-km locally available raw materials was investigated, namely: (1) plasters with recycled materials; (2) plasters with natural fibers; and (3) building insulation materials with natural fibers. Results indicate that the investigated materials were able to improve not only the energy per-formances but also the environmental comfort in both new and in existing buildings. In particular, plasters and mortars with recycled materials and with natural fibers showed, respectively, values of thermal conductivity (at 20 °C) lower than 0.475 and 0.272 W/(mK), while that of building materials with natural fibers was always lower than 0.162 W/(mK) with lower values for com-pounds with recycled materials (0.107 W/(mK)). Further developments are underway to analyze the mechanical properties of these materials

    Towards improved humidity measurements at high temperatures and transient conditions

    Get PDF
    Humidity is a key parameter in controlling drying processes and ambient conditions in many industrial manufacturing, storage and test applications. Air humidity is routinely measured at temperatures above 100 °C and at conditions that are often challenging due to temporal and local variations. Calibrations of humidity sensors do not provide appropriate representativeness of measurement conditions because they are limited to temperatures below 100 °C and static conditions. A European metrology research project HIT (“Metrology for Humidity at High Temperatures and Transient conditions”) is developing improved humidity measurement and calibration techniques to temperatures up to 180 °C and non-static conditions. This paper summaries developments of the project: calibration and test facilities for industrial hygrometers, studies on humidity control in specific microbial transient processes and a new measurement approach for water activity measurements

    Impact of Hydrogen Injection on Natural Gas Measurement

    No full text
    Hydrogen is increasingly receiving a primary role as an energy vector in ensuring the achievement of the European decarbonization goals by 2050. In fact, Hydrogen could be produced also by electrolysis of water using renewable sources, such as photovoltaic and wind power, being able to perform the energy storage function, as well as through injection into natural gas infrastructures. However, hydrogen injection directly impacts thermodynamic properties of the gas itself, such as density, calorific value, Wobbe index, sound speed, etc. Consequently, this practice leads to changes in metrological behavior, especially in terms of volume and gas quality measurements. In this paper, the authors present an overview on the impact of hydrogen injection in natural gas measurements. In particular, the changes in thermodynamic properties of the gas mixtures with different H2 contents have been evaluated and the effects on the accuracy of volume conversion at standard conditions have been investigated both on the theoretical point of view and experimentally. To this end, the authors present and discuss the effect of H2 injection in gas networks on static ultrasonic domestic gas meters, both from a theoretical and an experimental point of view. Experimental tests demonstrated that ultrasonic gas meters are not significantly affected by H2 injection up to about 10%
    corecore